For FPC fabric management, use the [set chassis fpc] CLI command to manage FPC online and offline states gracefully. Ungraceful FPC removal and insertion do not affect system stability; the system remains responsive, and other online FPCs continue to carry traffic.
Use the [set chassis fabric event reachability-fault] command to configure options for detecting fabric reachability faults and trigger automatic connectivity restoration.
Use the extended keyword in [show chassis fabric fpcs] and [show chassis fabric sibs] commands to view detailed link information within planes. Identify partially enabled planes with the Degraded keyword in [show chassis fabric fpcs] command.
For an application service module line card (AS MLC), use the following CLI operational mode commands display fabric-related information:
| Product / Application | Software | Introduced Release |
|---|---|---|
| MX204 | Junos OS | 17.4R1 |
| MX240 | Junos OS | 16.1R1 |
| MX240 | Junos OS | 12.1R3 |
| MX301 | Junos OS | 25.4R1 |
| MX304 | Junos OS | 22.2R3 |
| MX480 | Junos OS | 16.1R1 |
| MX480 | Junos OS | 12.1R3 |
| MX960 | Junos OS | 16.1R1 |
| MX960 | Junos OS | 12.1R3 |
| MX10003 | Junos OS | 17.3R1 |
| MX10004 | Junos OS | 24.2R1 |
| MX10004 | Junos OS | 22.3R1 |
| MX10008 | Junos OS | 24.2R1 |
| MX10008 | Junos OS | 18.2R1 |
| MX10016 | Junos OS | 19.2R1 |
| PTX10008 | Junos OS Evolved | 25.4R1 |
| PTX10008 | Junos OS Evolved | 24.4R2 |
| PTX10008 | Junos OS Evolved | 24.4R1-S2 |
| PTX10002-36QDD | Junos OS Evolved | 24.4R1 |
| PTX10002-36QDD | Junos OS Evolved | 24.2R2 |