Feature Explorer AI AI

×

Subscribe now to get the Latest Updates

Watch a 2-minute overview video

Configuring chassis ambient temperature to monitor power consumption of FPCs

More Information:

Configuring chassis ambient temperature to monitor power consumption of FPCs

You can set the ambient temperature of the chassis at 25° C or 40° C. On system initialization, the power manager reads the ambient temperature and allocates power to the FPCs according to the power budget policy at that temperature. If any FPC consumes more power than the configured value for more than 3 minutes, the PWR Range Overshoot alarm is raised for that FPC, and the power manager overrides the configured ambient temperature setting of that FPC and resets its ambient temperature to the next higher level and reallocates power according to the new temperature setting. All the overshooting FPCs remain in the dynamic ambient temperature mode until the next reboot, or until you override it with a CLI command. The power manager then resets the power budget of the FRUs, including the overshooting FPCs, according to the configured ambient temperature setting. To configure the ambient temperature, include the set chassis ambient-temperature statement at the [edit] hierarchy level.
Product / Application Software Introduced Release
EX9200 Junos OS 15.1R1
EX9251 Junos OS 18.1R1
EX9253 Junos OS 18.2R1
MX5 Junos OS 15.1R1
MX10 Junos OS 15.1R1
MX40 Junos OS 15.1R1
MX80 Junos OS 15.1R1
MX104 Junos OS 15.1R1
MX150 Junos OS 17.3R1
MX204 Junos OS 17.4R1
MX240 Junos OS 15.1R1
MX301 Junos OS 25.4R1
MX304 Junos OS 22.2R3
MX480 Junos OS 15.1R1
MX960 Junos OS 15.1R1
MX2008 Junos OS 15.1F7
MX2010 Junos OS 15.1R1
MX2020 Junos OS 15.1R1
MX10003 Junos OS 17.3R1
MX10004 Junos OS 22.3R1
MX10008 Junos OS 18.2R1
MX10016 Junos OS 19.2R1
vMX Junos OS 15.1F3
PTX1000 Junos OS 16.1X65-D30
PTX3000 Junos OS 15.1R1
PTX5000 Junos OS 15.1R1
PTX10008 Junos OS 17.2R1
PTX10016 Junos OS 17.4R1
SRX5800 Junos OS 15.1X49-D10