Ambient-temperature statement enhancement

More Information:

Ambient-temperature statement enhancement

The default ambient temperature is set at 40° C on devices.You can override ambient temperature by setting the temperature at 55° C or 25° C. When a device restarts, the system adjusts the power allocation or the provisioned power for the line cards on the basis of the configured ambient temperature. If enough power is not available, a minor chassis alarm is raised. However, the chassis continues to run with the configured ambient temperature. You can configure a new higher ambient temperature only after you make more power available by adding new power supply modules or by taking a few line cards offline. By using the provisioned power that is saved by configuring a lower ambient temperature, you can bring more hardware components online.
Product / Application Software Introduced Release
EX9200 Junos OS 15.1R3
EX9251 Junos OS 18.1R1
EX9253 Junos OS 18.2R1
MX204 Junos OS 17.4R1
MX301 Junos OS 25.4R1
MX304 Junos OS 22.2R3
MX480 Junos OS 15.1F4
MX960 Junos OS 15.1F4
MX2008 Junos OS 15.1F7
MX2010 Junos OS 15.1F4
MX2020 Junos OS 15.1F4
MX10003 Junos OS 17.3R1
MX10004 Junos OS 22.3R1
MX10008 Junos OS 18.2R1
MX10016 Junos OS 19.2R1
PTX1000 Junos OS 16.1X65-D30
PTX3000 Junos OS 15.1F4
PTX5000 Junos OS 15.1F4