Enhanced fault management features

More Information:

Enhanced fault management features

Devices support configuration of error thresholds and actions at the error scope and error category levels. Use the command set chassis fpc fpc-slot error scope error-scope category category (fatal | major | minor) threshold error-threshold action (alarm | disable-pfe | get-state | offline | log | reset) to configure a threshold and action for a particular error scope and category at the FPC level. You can also configure these features at the chassis level (at the [edit chassis] hierarchy). You can use the command show chassis fpc errors to view the error information at the error scope and category level.
Product / Application Software Introduced Release
MX2010 Junos OS 18.1R3