You can configure a device to bring associated interfaces down (hard shutdown) when the device detects an EVPN core isolation event.
In the CLI:
1. Define a service tracking profile for detecting core isolation conditions.
2. Set the link-down service tracking action in the profile.
3. Assign the profile to the interfaces you want the device to bring down after it detects a core isolation condition.
We support core isolation service tracking on:
| Product / Application | Software | Introduced Release |
|---|---|---|
| ACX7024 | Junos OS Evolved | 24.4R1 |
| ACX7100-32C | Junos OS Evolved | 24.4R1 |
| ACX7100-48L | Junos OS Evolved | 24.4R1 |
| EX4400 Multigigabit | Junos OS | 23.2R1 |
| MX301 | Junos OS | 25.4R1 |
| MX304 | Junos OS | 23.2R1 |
| MX10003 | Junos OS | 23.2R1 |
| QFX5120-48Y | Junos OS | 23.2R1 |
| QFX5120-32C | Junos OS | 23.2R1 |
| QFX5130-32CD | Junos OS Evolved | 23.2R1 |
| QFX5130E-32CD | Junos OS Evolved | 23.4R2 |
| QFX5130-48C | Junos OS Evolved | 23.4R1 |
| QFX5130-48CM | Junos OS Evolved | 23.4R2 |
| QFX5120-48T | Junos OS | 23.2R1 |
| QFX5120-48YM | Junos OS | 23.2R1 |
| QFX5700 | Junos OS Evolved | 23.2R1 |
| QFX5700E | Junos OS Evolved | 23.4R2 |
| QFX5140-24CD8O | Junos OS Evolved | 25.2X100-D20 |