Loading...
| Product | Max Ambient Temp | Fan Speed | First release | Port Population Guidelines | General Guidelines |
|---|---|---|---|---|---|
| ACX7100-32C | Sea level: 34°C 6000 ft: 28°C | Use temperature-sensor to set manually | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | - |
| ACX7100-48LAFO | Sea level: 42°C 6000 ft: 36°C | Use temperature-sensor to set manually | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | - |
| ACX7300-2DC4C with ACX7332 or ACX7348 | Sea level: 40°C 6000 ft: 34°C | SW Policy controlled | Junos OS 23.4R1 | All QSFP56-DD ports can be used | - |
| MX10004 with MX10K-LC9600 | Sea level: 38°C 6000 ft: 32°C | Use temperature-sensor to set manually | Junos OS 23.4R1 | All QSFP56-DD ports can be used | - |
| Sea level: 38°C 6000 ft: 32°C | Use temperature-sensor to set manually | Junos OS 24.4R1 | All QSFP56-DD ports can be used | ZR/ZR+ optics cannot be supported with low power mode enabled (set chassis fpc-empolicy-profile low-power-mode). Please ensure low power mode is not configured. | |
| MX10008 with MX10K-LC9600 | Sea level: 46°C 6000 ft: 40°C | SW Policy controlled | Junos OS 23.4R1 | All QSFP56-DD ports can be used | - |
| Sea level: 46°C 6000 ft: 40°C | SW Policy controlled | Junos OS 24.4R1 | All QSFP56-DD ports can be used | ZR/ZR+ optics cannot be supported with low power mode enabled (set chassis fpc-empolicy-profile low-power-mode). Please ensure low power mode is not configured. | |
| MX304 with MX304-LMIC | Sea level: 46°C | Use temperature-sensor to set manually | Junos OS 23.4R1 | All QSFP56-DD ports can be used | - |
| PTX10001-36MR | Sea level: 39°C 6000 ft: 33°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | Top ports: Max (12) 400G ZR with no restrictions. All other ports: Remaining can be used with up to 3.5W optics (QSFP28 ports) or 12W optics (QSFP56-DD ports) as long as power zone restrictions are not violated. | PTX10001-36MR Power Zone Restrictions |
| Sea level: 39°C 6000 ft: 33°C | SW Policy controlled | Junos OS Evolved 23.4R1 | Top ports: Max (12) 400G ZR with no restrictions. All other ports: Remaining can be used with up to 3.5W optics (QSFP28 ports) or 12W optics (QSFP56-DD ports) as long as power zone restrictions are not violated. | PTX10001-36MR Power Zone Restrictions | |
| PTX10002-36QDD | Sea level: 46°C 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.4R2 | All QSFP56-DD ports can be used | - |
| PTX10004 with PTX10K-LC1201-36CD | Sea level, All slots: 35°C 6000 ft, Slot 0: 32°C 6000 ft, Slots 1-3: 35°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C |
| Sea level, All slots: 35°C 6000 ft, Slot 0: 34°C 6000 ft, Slots 1-3: 35°C | SW Policy controlled | Junos OS Evolved 23.4R1 | Top ports: all QSFP56-DD ports can be used Bottom ports: Remaining QSFP56-DD ports can be populated with optics consuming 12W or less | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C | |
| PTX10004 with PTX10K-LC1202-36MR | Sea level, All slots: 43°C 6000 ft, Slot 0: 37°C 6000 ft, Slots 1-3: 40°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C |
| PTX10008 with PTX10K-LC1201-36CD | Sea level: 35°C 6000 ft: 32°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C |
| Sea level: 35°C 6000 ft: 34°C | SW Policy controlled | Junos OS Evolved 23.4R1 | Top ports: all QSFP56-DD ports can be used Bottom ports: Remaining QSFP56-DD ports can be populated with optics consuming 12W or less | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C | |
| PTX10008 with PTX10K-LC1202-36MR | Sea level: 43°C 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C |
| PTX10016 with PTX10K-LC1201-36CD | Sea level: 34°C 6000 ft: 31°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C |
| Sea level: 34°C 6000 ft: 33°C | SW Policy controlled | Junos OS Evolved 23.4R1 | Top ports: all QSFP56-DD ports can be used Bottom ports: Remaining QSFP56-DD ports can be populated with optics consuming 12W or less | Installation of the air filter door reduces the maximum ambient temperature limit by 3°C | |
| PTX10016 with PTX10K-LC1202-36MR | Sea level: 43°C 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3°C |
| QFX5130-32CD AFO, QFX5130E-32CD AFO | Sea level: 40°C 6000 ft: 34°C | SW Policy controlled | Junos OS Evolved 25.4R1 | Populate QSFP56-DD ports with zig-zag placement of optics starting with port 0/0/0. All unused ports should be disabled. | - |
| QFX5130-32CD AFI, QFX5130E-32CD AF | Sea level: 35°C 6000 ft: 29°C | SW Policy controlled | Junos OS Evolved 25.4R1 | Populate QSFP56-DD ports with zig-zag placement of optics starting with port 0/0/0. All unused ports should be disabled. | - |