| Parameter | Value |
|---|---|
| Cable type | MMF |
| Core size/cladding | 50/125 µm |
| Digital Diagnostic Monitoring | Module Case Temperature Supply voltage TX bias current TX power RX power |
| Distance | OM3: 0.5 m to 30 m OM4: 0.5 m to 50 m OM5: 0.5 m to 50 m |
| Maximum Power consumption (W) | 16 W |
| NEBs (Yes or No) | No |
| Operating Temperature (range) | 0°C to 70°C |
| Optic Type (Commercial Vs Service Provider Grade) | Commercial |
| Receive lane wavelengths (range) | 840 to 868 nm |
| Receiver input average power, each lane (maximum) | 4 dBm |
| Receiver input average power, each lane (minimum) | -6.3 dBm |
| Receiver sensitivity (OMA), each lane (maximum) | For TECQ ≤ 1.8 dB: -4.4 dBm For 1.8 < TECQ ≤ 4.4 dB: (-6.2 + TECQ) dBm |
| Signaling rate, each lane | . 400GBASE-VR4, 200GBASE-VR2, and 100GBASE-VR1: Host lane: PAM4; 53.125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm . 800GBASE-VR8: Host lane: PAM4; 53.125 GBd ± 50 ppm Media lane: PAM4; 53.125 GBd ± 50 ppm . 400G-SR8, 200G-SR4, 100G-SR2, and 50G-SR Host lane: PAM4; 26.5625 GBd ± 100 ppm Media lane: PAM4; 26.5625 GBd ± 100 ppm |
| Storage temperature | -40°C to 85°C |
| Supported Breakouts | (1) Maximum 1 instance of 800GBASE-VR8 (2) Maximum 2 instances of 400GBASE-VR4 (3) Maximum 4 instances of 200GBASE-VR2 (4) Maximum 8 instances of 100GBASE-VR1 (5) Maximum 1 instance of 400G-SR8 (6) Maximum 2 instances of 200G-SR4 (7) Maximum 4 instances of 100G-SR2 (8) Maximum 8 instances of 50G-SR |
| Transmitter fibers | 8 |
| Transmitter output average power, each lane (maximum) | 4 dBm |
| Transmitter output average power, each lane (minimum) | -4.6 dBm |
| Transmitter wavelengths (range) | 842 to 868 nm |
| Typical Weight & Dimensions | Weight: 0.2 kg Height: 14.70 mm Width: 22.93 mm Depth: 116.40 mm |
| Parameter | Value |
|---|---|
| Cable type | MMF |
| Core size/cladding | 50/125 µm |
| Digital Diagnostic Monitoring | Module Case Temperature Supply voltage TX bias current TX power RX power |
| Distance | OM3: 0.5 m to 30 m OM4: 0.5 m to 50 m OM5: 0.5 m to 50 m |
| Maximum Power consumption (W) | 16 W |
| NEBs (Yes or No) | No |
| Operating Temperature (range) | 0°C to 70°C |
| Optic Type (Commercial Vs Service Provider Grade) | Commercial |
| Receive lane wavelengths (range) | 840 to 868 nm |
| Receiver input average power, each lane (maximum) | 4 dBm |
| Receiver input average power, each lane (minimum) | -6.3 dBm |
| Receiver sensitivity (OMA), each lane (maximum) | For TECQ ≤ 1.8 dB: -4.4 dBm For 1.8 < TECQ ≤ 4.4 dB: (-6.2 + TECQ) dBm |
| Signaling rate, each lane | . 400GBASE-VR4, 200GBASE-VR2, and 100GBASE-VR1: Host lane: PAM4; 53.125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm . 800GBASE-VR8: Host lane: PAM4; 53.125 GBd ± 50 ppm Media lane: PAM4; 53.125 GBd ± 50 ppm . 400G-SR8, 200G-SR4, 100G-SR2, and 50G-SR Host lane: PAM4; 26.5625 GBd ± 100 ppm Media lane: PAM4; 26.5625 GBd ± 100 ppm |
| Storage temperature | -40°C to 85°C |
| Supported Breakouts | (1) Maximum 1 instance of 800GBASE-VR8 (2) Maximum 2 instances of 400GBASE-VR4 (3) Maximum 4 instances of 200GBASE-VR2 (4) Maximum 8 instances of 100GBASE-VR1 (5) Maximum 1 instance of 400G-SR8 (6) Maximum 2 instances of 200G-SR4 (7) Maximum 4 instances of 100G-SR2 (8) Maximum 8 instances of 50G-SR |
| Transmitter fibers | 8 |
| Transmitter output average power, each lane (maximum) | 4 dBm |
| Transmitter output average power, each lane (minimum) | -4.6 dBm |
| Transmitter wavelengths (range) | 842 to 868 nm |
| Typical Weight & Dimensions | Weight: 0.2 kg Height: 14.70 mm Width: 22.93 mm Depth: 116.40 mm |