Loading...
| Parameter | Value |
|---|---|
| Cable type | MMF |
| Core size/cladding | 50/125 μm |
| Digital Diagnostic Monitoring | Module Case Temperature Power Supply voltage TX bias current TX power RX power |
| Distance | 0.5 m to 70 m for OM3 0.5 m to 100 m for OM4 0.5 m to 150 m for OM5 |
| Effective modal bandwidth at 850 nm (min) | OM3: 2000 MHz x km OM4: 4700 MHz x km OM5: 4700 MHz x km |
| Effective modal bandwidth at 910 nm (min) | OM3: 1260 MHz x km OM4: 1980 MHz x km OM5: 3100 MHz x km |
| Fiber grade | OM3, OM4, OM5 |
| Max Distance(km) | 0.15 |
| Maximum Power consumption (W) | 12 W |
| Operating Temperature (range) | 0° C to 70° C |
| Optic Type (Commercial Vs Service Provider Grade) | Commercial |
| Receive lane wavelengths (range) | λ1 for TxRx pair type RT: 844 to 863 nm λ2 for TxRx pair type TR: 900 to 918 nm |
| Receiver input power (maximum) | 4 dBm |
| Receiver input power (minimum) | -8.2 dBm |
| Receiver sensitivity ([Equation]), each lane (maximum) | max(−6.6, SECQ−8) dBm |
| Signaling rate, each lane | Host lane: PAM4; 26.5625 GBd ± 100 ppm Media lane: PAM4; 26.5625 GBd ± 100 ppm |
| Standards compliance (Ethernet/OTN Standard, for e.g. 100GBASE-LR4) | IEEE Std 802.3-2022, Clause 150, 400GBASE-SR4.2 |
| Storage temperature | –40° C to 85° C |
| Stressed receiver sensitivity (OMA) each lane (maximum) | -3.5 dBm |
| Supported Breakouts | . Maximum 1 instance of 400GBASE-SR4.2 . Maximum 4 instances of 100GE BiDi (100GE-SR1.2) |
| Transmitter fibers | 4 |
| Transmitter output power (maximum) | 4 dBm |
| Transmitter output power (minimum) | -6.2 dBm |
| Transmitter wavelengths (range) | λ1 for TxRx pair type TR: 844 to 863 nm λ2 for TxRx pair type RT: 900 to 918 nm |
| Typical Weight & Dimensions | Weight: 0.2 kg Height: 13.5 mm Width: 18.35 mm Depth: 93.26 mm |