| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| Full Product Name | PTX12008 Router | PTX12008 Router | PTX12008 Router | PTX12008 Router |
| OS Supported | Junos OS Evolved | Junos OS Evolved | Junos OS Evolved | Junos OS Evolved |
| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| Fixed/Modular Chassis? | Modular | Modular | Modular | Modular |
| Form Factor | 22 U | 22 U | 22 U | 22 U |
| Chassis Height | 37.50 in / 95.25 cm | 37.50 in / 95.25 cm | 37.50 in / 95.25 cm | 37.50 in / 95.25 cm |
| Chassis Width | 18.90 in / 48.006 cm | 18.90 in / 48.006 cm | 18.90 in / 48.006 cm | 18.90 in / 48.006 cm |
| Chassis Depth | 36.10 in / 91.694 cm | 36.10 in / 91.694 cm | 36.10 in / 91.694 cm | 36.10 in / 91.694 cm |
| Chassis Depth (With Front Door with EMI Deflectors) | 43.20 in / 109.728 cm | 43.20 in / 109.728 cm | 43.20 in / 109.728 cm | 43.20 in / 109.728 cm |
| Chassis Weight (Spare) | 325 lb / 147.42 kg | 325 lb / 147.42 kg | 325 lb / 147.42 kg | 325 lb / 147.42 kg |
| Cable Management System Model Number | PTX12K-CM | PTX12K-CM | PTX12K-CM | PTX12K-CM |
| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| PSU Count | 20 | 20 | 12 | 12 |
| PSU Airflow Direction | Front-to-back | Front-to-back | Front-to-back | Front-to-back |
| PSU Hot-Removable And Hot-Insertable? | Y | Y | Y | Y |
| AC PSU Model Number | JNP-PWR-3K-AC | - | JNP-PWR-3K-AC | - |
| Grounding Cable Lug Type | Panduit LCD4-14A-L or equivalent | Panduit LCD4-14A-L | Panduit LCD4-14A-L or equivalent | Panduit LCD4-14A-L or equivalent |
| Grounding Cable Wire Gauge | 4 AWG | 4 AWG | 4 AWG | 4 AWG |
| DC PSU Model Number | - | JNP-PWR-3K-DC | - | JNP-PWR-3K-DC |
| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| Airflow Direction | Front-to-back | Front-to-back | Front-to-back | Front-to-back |
| AFO/AFI? | AFO | AFO | AFO | AFO |
| Fan Tray Model Number | PTX12008-FAN | PTX12008-FAN | PTX12008-FAN | PTX12008-FAN |
| Fan Tray Count | 3 | 2 | 3 | 3 |
| Fan Tray Hot-Removable And Hot-Insertable? | Y | Y | Y | Y |
| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| RE Model Number | PTX12K-RE | PTX12K-RE | PTX12K-RE | PTX12K-RE |
| RE Count | 2 | 2 | 1 | 1 |
| RE Hot-Pluggable? | Primary | Primary | - | - |
| RE Hot-Removable And Hot-Insertable? | Backup | Backup | - | - |
| SFB Count | 9 | 9 | 3 | 3 |
| SFB Hot-Removable And Hot-Insertable? | Y | Y | Y | Y |
| Module Slots | 8 | 8 | 8 | 8 |
| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| Operating Temperature | 32° through 104° F / 0° through 40° C | 32° through 104° F / 0° through 40° C | 32° through 104° F / 0° through 40° C | 32° through 104° F / 0° through 40° C |
| Storage Temperature | -40° through 158° F / -40° through 70° C | -40° through 158° F / -40° through 70° C | -40° through 158° F / -40° through 70° C | -40° through 158° F / -40° through 70° C |
| Operating Altitude | 6000 ft / 1828.800 m | 6000 ft / 1828.800 m | 6000 ft / 1828.800 m | 6000 ft / 1828.800 m |
| Relative Humidity, Noncondensing (Operating) | 5% through 90% | 5% through 90% | 5% through 90% | 5% through 90% |
| Seismic Tolerance | Zone 4 | Zone 4 | Zone 4 | Zone 4 |
| Maintenance Clearance | 24 in / 60.96 cm | 24 in / 60.96 cm | 24 in / 60.96 cm | 24 in / 60.96 cm |
| Attribute Name | PTX12008-PREMIUM (AC) | PTX12008-PREMIUM (DC) | PTX12008-BASE (AC) | PTX12008-BASE (DC) |
|---|---|---|---|---|
| Throughput | 345.6 Tbps | 345.6 Tbps | 345.6 Tbps | 345.6 Tbps |