CHASSISD_CB_MASTER_BP_IGNORED
Filter Releases
Specific system log message Information:
Name
CHASSISD_CB_MASTER_BP_IGNORED
Message
Press of online/offline button ignored for master <variable>fru-name</variable> <variable>fru-slot</variable>
Help
Press of online button ignored for master control board
Description
The online/offline button for the indicated control board was pressed, but the chassis process (chassisd) ignored the request. The control board for M40e and M160 routers is the Miscellaneous Control Subsystem (MCS). The control board for M320, T320, T640, MX240, MX480 and MX960 routers is the Control Board (CB).
Type
Event: This message reports an event, not an error
Severity
error
Cause
The control board was acting as master.
Facility
LOG_DAEMON
Action
Switch mastership to the other control board before taking the control board offline.