Compare System Log Messages
Compare system log messages in two different software releases.
Select two Releases to Compare
Unique system log messages in
Unique system log messages in
Unique system log messages in
Unique system log messages in
Common log messages
No information available.
CHASSISD_FM_ERROR_CLOS_F13_HSR
Filter Releases
Specific system log message Information:
Name
CHASSISD_FM_ERROR_CLOS_F13_HSR
Message
FM: <variable>error-message</variable> errors occurred on link from F2S-<variable>f2-sib</variable>_SF<variable>from-fchip</variable>_<variable>s-port</variable> to F13SIB<variable>to-sfc-sib</variable>_SF3_<variable>to-fchip</variable>_<variable>d-port</variable> on plane <variable>sib-plane</variable>
Help
Error in electrical path between F13SIB and F2SIB
Description
In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs). The chassis process (chassisd) on the SFC routing node detected an error in the electrical path between the indicated port on the indicated F2SIB and F13SIB on the indicated plane.
Type
Error: An error occurred
Severity
error
Cause
Facility
LOG_DAEMON
Action
Contact your technical support representative.
Attributes
error-message
f2-sib
from-fchip
s-port
to-sfc-sib
to-fchip
d-port
sib-plane
CHASSISD_FM_ERROR_CLOS_F13_HSR available in the following releases: