Compare System Log Messages
Compare system log messages in two different software releases.
Select two Releases to Compare
Unique system log messages in
Unique system log messages in
Unique system log messages in
Unique system log messages in
Common log messages
No information available.
COSD_CLASSIFIER_IFD_REFERENCE_COUNT_IS_ZERO
Filter Releases
Specific system log message Information:
Name
COSD_CLASSIFIER_IFD_REFERENCE_COUNT_IS_ZERO
Message
<variable>function-name</variable>:<variable>line-number</variable> : Classifer reference count on interface <variable>interface-name</variable> is zero
Help
IFD classifier reference count is zero
Description
When a CoS classifier is bound to an interface, then the classifier's interface reference count will be incremented. When the reference count value is zero then it means the classifier is not bound to any interface.
Type
Internal: Internal log message
Severity
error
Cause
An internal software failure occurred.
Facility
LOG_DAEMON
Action
Contact your technical support representative.
Attributes
function-name
line-number
interface-name
COSD_CLASSIFIER_IFD_REFERENCE_COUNT_IS_ZERO available in the following releases: