Compare System Log Messages
Compare system log messages in two different software releases.
Select two Releases to Compare
Unique system log messages in
Unique system log messages in
Unique system log messages in
Unique system log messages in
Common log messages
No information available.
DCD_MSG_LEN_MISMATCH_PFE_OPTS
Filter Releases
Specific system log message Information:
Name
DCD_MSG_LEN_MISMATCH_PFE_OPTS
Message
<variable>message-name</variable> PFE options length mismatch (<variable>received-value</variable> != <variable>expected-value</variable>u)
Help
The message PFE options length was unexpected
Description
DCD communicates with the kernel through its routing sockets. When a message arrives on a routing socket, DCD performs basic checking of the various lengths of the fields in the message. DCD received a message with an unexpected length for a field.
Type
Internal: Internal log message
Severity
error
Cause
There is a bug in DCD, or in the routing socket or driver in the kernel.
Facility
LOG_DAEMON
Action
Contact your technical support representative.
Attributes
message-name
received-value
expected-value
DCD_MSG_LEN_MISMATCH_PFE_OPTS available in the following releases: