Loading...
| Product | Max Ambient Temp | Fan Speed | First release | Port Population Guidelines | General Guidelines |
|---|---|---|---|---|---|
| ACX7100-32C | Sea level: 34°C / 6000 ft: 28°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | - |
| ACX7100-48L AFO | Sea level: 40°C / 6000 ft: 34°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | - |
| MX10004 with MX10K-LC9600 | Sea level: 41°C / 6000 ft: 35°C | Use temperature-sensor to set manually | Junos OS 23.2R1 | All QSFP56-DD ports can be used | - |
| MX10008 with MX10K-LC9600 | Sea level: 43°C / 6000 ft: 37°C | Use temperature-sensor to set manually | Junos OS 23.2R1 | All QSFP56-DD ports can be used | - |
| MX304 with MX304-LMIC | Sea level: 43°C / 6000 ft: 37°C | SW Policy controlled | Junos OS 23.2R1 | All QSFP56-DD ports can be used | - |
| PTX10001-36MR | Sea level: 37°C / 6000 ft: 31°C | Use temperature-sensor to set manually | Junos OS Evolved 23.1R1 | Top ports: Max (12) 400G ZR with no restrictions. All other ports: Remaining can be used with up to 3.5W optics (QSFP28 ports) or 12W optics (QSFP56-DD ports) as long as power zone restrictions are not violated. | PTX10001-36MR Power Zone Restrictions |
| Sea level: 37°C / 6000 ft: 31°C | SW Policy controlled | Junos OS Evolved 23.4R1 | Top ports: Max (12) 400G ZR with no restrictions. All other ports: Remaining can be used with up to 3.5W optics (QSFP28 ports) or 12W optics (QSFP56-DD ports) as long as power zone restrictions are not violated. | PTX10001-36MR Power Zone Restrictions | |
| PTX10002-36QDD | Sea level: 46°C / 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.4R2 | All QSFP56-DD ports can be used | - |
| PTX10004 with PTX10K-LC1201-36CD | Sea level, All slots: 38°C / 6000 ft, Slot 0: 32°C / 6000 ft, Slots 1-3: 35°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |
| Sea level, All slots: 38°C / 6000 ft, Slot 0: 32°C / 6000 ft, Slots 1-3: 35°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C | |
| PTX10004 with PTX10K-LC1202-36MR | Sea level, All slots: 41°C / 6000 ft, Slot 0: 35°C / 6000 ft, Slots 1-3: 38°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |
| Sea level, All slots: 41°C / 6000 ft, Slot 0: 35°C / 6000 ft, Slots 1-3: 38°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C | |
| PTX10008 with PTX10K-LC1201-36CD | Sea level: 38°C / 6000 ft: 35°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |
| Sea level: 38°C / 6000 ft: 35°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C | |
| PTX10008 with PTX10K-LC1201-36MR | Sea level: 41°C / 6000 ft: 38°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |
| Sea level: 41°C / 6000 ft: 38°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C | |
| PTX10016 with PTX10K-LC1201-36CD | Sea level: 34°C / 6000 ft: 31°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |
| PTX10016 with PTX10K-LC1201-36MR | Sea level: 41°C / 6000 ft: 38°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |
| Sea level: 41°C / 6000 ft: 38°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Air Filter Door installed reduces the maximum ambient temperature limit by 3C |