Loading...
| Product | Max Ambient Temp | Fan Speed | First release | Port Population Guidelines | General Guidelines |
|---|---|---|---|---|---|
| ACX7100-32C | Sea level: 40°C / 6000 ft: 34°C | Use temperature-sensor to set manually | Junos OS Evolved 21.4R1 | All QSFP56-DD ports can be used | - |
| ACX7100-48L AFO | Sea level: 42°C / 6000 ft: 36°C | Use temperature-sensor to set manually | Junos OS Evolved 21.4R1 | All QSFP56-DD ports can be used | - |
| ACX7348 or ACX7332 with ACX7300-FPC-2CD4C | Sea level: 46°C, 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | - |
| ACX7509 with JNP-FPC-4CD | Sea level: 46°C, 6000 ft: 40°C | Use temperature-sensor to set manually | Junos OS Evolved 23.2R1 | All QSFP56-DD ports can be used | - |
| MX10004 with MX10K-LC9600 | Sea level: 43°C / 6000 ft: 37°C | Use temperature-sensor to set manually | Junos OS 22.2R1 | All QSFP56-DD ports can be used | - |
| MX10008 with MX10K-LC9600 | Sea level: 46°C / 6000 ft: 40°C | SW Policy controlled | Junos OS 22.2R1 | All QSFP56-DD ports can be used | - |
| MX240 or MX480 with MPC10E-10C or MPC10E-15C | Sea level: 34°C, 6000 ft: 28°C | SW Policy controlled | Junos OS 24.4R1 | All QSFP56-DD ports can be used | - |
| MX304 with MX304-LMIC | Sea level: 46°C | Use temperature-sensor to set manually | Junos OS 23.1R1 | All QSFP56-DD ports can be used | - |
| MX960 with MPC10E-10C or MPC10E-15C | Sea level: 28°C, 6000 ft: 22°C | SW Policy controlled | Junos OS 24.4R1 | All QSFP56-DD ports can be used | - |
| PTX10001-36MR | Sea level, All slots: 40°C / 6000 ft, Slot 0: 34°C | Use temperature-sensor to set manually | Junos OS Evolved 21.3R1 | Top ports: Max (12) 400G ZR with no restrictions. All other ports: Remaining can be used with up to 3.5W optics (QSFP28 ports) or 12W optics (QSFP56-DD ports) as long as power zone restrictions are not violated. | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. PTX10001-36MR Power Zone Restrictions |
| Sea level, All slots: 40°C / 6000 ft, Slot 0: 34°C | SW Policy controlled | Junos OS Evolved 23.4R1 | Top ports: Max (12) 400G ZR with no restrictions. All other ports: Remaining can be used with up to 3.5W optics (QSFP28 ports) or 12W optics (QSFP56-DD ports) as long as power zone restrictions are not violated. | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. PTX10001-36MR Power Zone Restrictions | |
| PTX10002-36QDD | Sea level: 46°C, 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.4R2 | All QSFP56-DD ports can be used | - |
| PTX10003 | Sea level: 40°C / 6000 ft: 34°C | SW Policy controlled | Junos OS Evolved 22.2R1 | All QSFP56-DD ports can be used | - |
| PTX10004 with PTX10K-LC1201-36CD | Sea level, All slots: 40°C / 6000 ft, Slot 0: 34°C / 6000 ft, Slots 1-3: 37°C | Use temperature-sensor to set manually | Junos OS Evolved 21.3R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C |
| Sea level, All slots: 40°C / 6000 ft, Slot 0: 34°C / 6000 ft, Slots 1-3: 37°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C | |
| PTX10004, PTX10008, and PTX10016 with PTX10K-LC1202-36MR | Sea level: 46°C / 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 21.3R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C |
| PTX10008 with PTX10K-LC1201-36CD | Sea level: 40°C / 6000 ft: 37°C | Use temperature-sensor to set manually | Junos OS Evolved 21.3R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C |
| Sea level: 40°C / 6000 ft: 37°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C | |
| PTX10016 with PTX10K-LC1201-36CD | Sea level: 36°C / 6000 ft: 33°C | Use temperature-sensor to set manually | Junos OS Evolved 21.3R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C |
| Sea level: 36°C / 6000 ft: 33°C | SW Policy controlled | Junos OS Evolved 23.4R1 | All QSFP56-DD ports can be used | Recommended to populate to QSFP56-DD ports with QDD-400G-ZR optics before populating bottom ports. Air Filter Door installed reduces the maximum ambient temperature limit by 3°C | |
| QFX5130-32CD | Sea level: 40°C, 6000 ft: 34°C | SW Policy controlled | Junos OS Evolved 23.1R1 | Max (16) with zig-zag placement of optics starting with port 0/0/0. All unused ports should be disabled. | - |
| QFX5220-32CD | Sea level: 46°C, 6000 ft: 40°C | SW Policy controlled | Junos OS Evolved 23.1R1 | Max (16) with zig-zag placement of optics starting with port 0/0/0. All unused ports should be disabled. | - |