Loading...
| Parameter | Value |
|---|---|
| Cable type | SMF |
| Core size/cladding | 9/125 µm |
| Digital Diagnostic Monitoring | Module Case Temperature Supply voltage TX bias current TX power RX power |
| Distance | 2 m to 2 km |
| Maximum Power consumption (W) | High Power Mode: 16 W Low Power Mode: 2 W |
| NEBs (Yes or No) | No |
| Operating Temperature (range) | 0°C to 70°C |
| Optic Type (Commercial Vs Service Provider Grade) | Commercial |
| Receive lane wavelengths (range) | 1304.5 to 1317.5 nm |
| Receiver input average power, each lane (maximum) | 4.5 dBm |
| Receiver input average power, each lane (minimum) | -7.1 dBm |
| Receiver sensitivity (OMA), each lane (maximum) | for TECQ < 1.4 dB: -4.5 dBm for 1.4 dB < TECQ < 3.4 dB: -5.9 + TECQ dBm |
| Signaling rate, each lane | . 400GBASE-DR4-2, 400GBASE-DR4, 200G-DR2-2-JUNIPER, 200G-DR2-JUNIPER, 100GBASE-FR1/100G-FR, 100GBASE-DR: Host lane: PAM4; 53.125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm . 800GBASE-DR8-2, 800GBASE-DR8: Host lane: PAM4; 53.125 GBd ± 50 ppm Media lane: PAM4; 53.125 GBd ± 50 ppm |
| Storage temperature | -40°C to 85°C |
| Supported Breakouts | (1) Maximum 1 instance of 800GBASE-DR8-2 or 800GBASE-DR8(2) Maximum 2 instances of 400GBASE-DR4-2 or 400GBASE-DR4(3) Maximum 4 instances of 200G-DR2-2-JUNIPER (Juniper custom code; comply with 400GBASE-DR4-2 optical specifications) or 200G-DR2-JUNIPER (Juniper custom code; comply with 400GBASE-DR4 optical specifications)(4) Maximum 8 instances of 100GBASE-FR1/100G-FR or 100GBASE-DR |
| Transmitter fibers | 8 |
| Transmitter output average power, each lane (maximum) | 4 dBm |
| Transmitter output average power, each lane (minimum) | -2.4 dBm |
| Transmitter wavelengths (range) | 1304.5 to 1317.5 nm |
| Typical Weight & Dimensions | Weight: 0.2 kg Height: 14.70 mm Width: 22.93 mm Depth: 116.40 mm |
| Parameter | Value |
|---|---|
| Cable type | SMF |
| Core size/cladding | 9/125 µm |
| Digital Diagnostic Monitoring | Module Case Temperature Supply voltage TX bias current TX power RX power |
| Distance | 2 m to 2 km |
| Maximum Power consumption (W) | High Power Mode: 16 W Low Power Mode: 2 W |
| NEBs (Yes or No) | No |
| Operating Temperature (range) | 0°C to 70°C |
| Optic Type (Commercial Vs Service Provider Grade) | Commercial |
| Receive lane wavelengths (range) | 1304.5 to 1317.5 nm |
| Receiver input average power, each lane (maximum) | 4.5 dBm |
| Receiver input average power, each lane (minimum) | -7.1 dBm |
| Receiver sensitivity (OMA), each lane (maximum) | for TECQ < 1.4 dB: -4.5 dBm for 1.4 dB < TECQ < 3.4 dB: -5.9 + TECQ dBm |
| Signaling rate, each lane | . 400GBASE-DR4-2, 400GBASE-DR4, 200G-DR2-2-JUNIPER, 200G-DR2-JUNIPER, 100GBASE-FR1/100G-FR, 100GBASE-DR: Host lane: PAM4; 53.125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm . 800GBASE-DR8-2, 800GBASE-DR8: Host lane: PAM4; 53.125 GBd ± 50 ppm Media lane: PAM4; 53.125 GBd ± 50 ppm |
| Storage temperature | -40°C to 85°C |
| Supported Breakouts | (1) Maximum 1 instance of 800GBASE-DR8-2 or 800GBASE-DR8(2) Maximum 2 instances of 400GBASE-DR4-2 or 400GBASE-DR4(3) Maximum 4 instances of 200G-DR2-2-JUNIPER (Juniper custom code; comply with 400GBASE-DR4-2 optical specifications) or 200G-DR2-JUNIPER (Juniper custom code; comply with 400GBASE-DR4 optical specifications)(4) Maximum 8 instances of 100GBASE-FR1/100G-FR or 100GBASE-DR |
| Transmitter fibers | 8 |
| Transmitter output average power, each lane (maximum) | 4 dBm |
| Transmitter output average power, each lane (minimum) | -2.4 dBm |
| Transmitter wavelengths (range) | 1304.5 to 1317.5 nm |
| Typical Weight & Dimensions | Weight: 0.2 kg Height: 14.70 mm Width: 22.93 mm Depth: 116.40 mm |
| Parameter | Value |
|---|---|
| Cable type | SMF |
| Core size/cladding | 9/125 µm |
| Digital Diagnostic Monitoring | Module Case Temperature Supply voltage TX bias current TX power RX power |
| Distance | 2 m to 2 km |
| Maximum Power consumption (W) | High Power Mode: 16 W Low Power Mode: 2 W |
| NEBs (Yes or No) | No |
| Operating Temperature (range) | 0°C to 70°C |
| Optic Type (Commercial Vs Service Provider Grade) | Commercial |
| Receive lane wavelengths (range) | 1304.5 to 1317.5 nm |
| Receiver input average power, each lane (maximum) | 4.5 dBm |
| Receiver input average power, each lane (minimum) | -7.1 dBm |
| Receiver sensitivity (OMA), each lane (maximum) | for TECQ < 1.4 dB: -4.5 dBm for 1.4 dB < TECQ < 3.4 dB: -5.9 + TECQ dBm |
| Signaling rate, each lane | . 400GBASE-DR4-2, 400GBASE-DR4, 200G-DR2-2-JUNIPER, 200G-DR2-JUNIPER, 100GBASE-FR1/100G-FR, 100GBASE-DR: Host lane: PAM4; 53.125 GBd ± 100 ppm Media lane: PAM4; 53.125 GBd ± 100 ppm . 800GBASE-DR8-2, 800GBASE-DR8: Host lane: PAM4; 53.125 GBd ± 50 ppm Media lane: PAM4; 53.125 GBd ± 50 ppm |
| Storage temperature | -40°C to 85°C |
| Supported Breakouts | (1) Maximum 1 instance of 800GBASE-DR8-2 or 800GBASE-DR8(2) Maximum 2 instances of 400GBASE-DR4-2 or 400GBASE-DR4(3) Maximum 4 instances of 200G-DR2-2-JUNIPER (Juniper custom code; comply with 400GBASE-DR4-2 optical specifications) or 200G-DR2-JUNIPER (Juniper custom code; comply with 400GBASE-DR4 optical specifications)(4) Maximum 8 instances of 100GBASE-FR1/100G-FR or 100GBASE-DR |
| Transmitter fibers | 8 |
| Transmitter output average power, each lane (maximum) | 4 dBm |
| Transmitter output average power, each lane (minimum) | -2.4 dBm |
| Transmitter wavelengths (range) | 1304.5 to 1317.5 nm |
| Typical Weight & Dimensions | Weight: 0.2 kg Height: 14.70 mm Width: 22.93 mm Depth: 116.40 mm |